Flat Panel Detector C-Arm

260X260mm

Flat Panel Detector

5.3kW HFG

10.4” Touch Screen

180º Dynamic Orbital

Rotation

Free Space 800mm

SID 1,000mm

DSA


Flat Panel Detector C-Arm

260X260mm

Flat Panel Detector

5.3kW HFG

10.4” Touch Screen

180º Dynamic 

Orbital Rotation

Free Space 800mm

SID 1,000mm

DSA


EXCELLENT IMAGE QUALITY

EXCELLENT 

IMAGE QUALITY

OPTIMIZED HFG


5.3kW HFG with stationary tube provides optimized
images with stable power. 


GENERATOR COOLING SYSTEM 


The generator cooling system prevents

overheating while allowing for longer usage

during operation.

OPTIMIZED HFG


5.3kW HFG with stationary tube provides optimized
images with stable power. 

GENERATOR COOLING SYSTEM 


The generator cooling system prevents

overheating while allowing for longer usage

during operation.

EASY-TO-USE SYSTEM  

LIVE IMAGE & COMMUNICATION


User-friendly 10.4" touch screen operation panel enables two-way communication between doctor and operator by using live image.

EASY-TO-USE SYSTEM

LIVE IMAGE & COMMUNICATION


User-friendly 10.4" touch screen operation panel enables two-way communication 

between doctor and operator by using live image.

WIDE FREE SPACE

& ORBITAL ROTATION


800mm free space and 180º orbital rotation provides convenient operation environment for operator.

WIDE FREE SPACE

& ORBITAL ROTATION


800mm free space and 180º orbital rotation provides convenient operation environment for operator.

RADIATION SAFETY SOLUTION  

LOW DOSE MODE


Low Dose Mode is a function that sets and manages the radiation dose automatically and provides the optimized image by the procedure type and site. 

It guarantees the safety of patients and medical staff who needs to be exposed by radiation dose for a long time during the procedure.

RADIATION SAFETY SOLUTION

LOW DOSE MODE


Low Dose Mode is a function that sets and manages the radiation
dose automatically and provides the optimized image by the procedure
type and site. It guarantees the safety of patients and medical staff who
needs to be exposed by radiation dose for a long time during the procedure.

AUTO / VIRTUAL COLLIMATION


auto collimation is a function that reduces the radiation dose after detecting/controlling the outside space of the target area. 

virtual collimation is a function that sets the customized area for reducing unnecessary radiation dose.

AUTO

VIRTUAL

AUTO / VIRTUAL COLLIMATION


auto collimation is a function that reduces the radiation dose after detecting/controlling the outside space of the target area. virtual collimation is a function that sets the customized area for reducing unnecessary radiation dose.

AUTO

VIRTUAL

ANGIOGRAPHY PACKAGE


DSA(Digital Subtraction Angiography) helps various clinical diagnosis and 

procedures through the vessel image information after injecting contrast medium.

ANGIOGRAPHY PACKAGE


DSA(Digital Subtraction Angiography) helps various clinical diagnosis and procedures through the vessel image information after injecting contrast medium.

APPLICATION SOFTWARE


ZENIS™ SOFTWARE

ZENIS™ SOFTWARE PROVIDES A TOTAL SOLUTION FROM OPERATION, 

IMAGE STORAGE, AND MANAGEMENT.

APPLICATION SOFTWARE


ZENIS™ SOFTWARE


ZENIS™ software provides a total solution from operation, image storage, and management.

CLINICAL IMAGES


Providing excellent diagnostic images through accumulated experience.

CLINICAL IMAGES


Providing excellent diagnostic images through accumulated experience.